You are here:
SKU: 6DR4004-6J

Siemens 6DR4004-6J SIPART PS2 Position Feedback Module

The Siemens 6DR4004-6J is an analog 4-20mA position feedback module designed for SIPART PS2 positioners, offering intrinsic safety and simple integration for valve control.

Product Overview

The Siemens 6DR4004-6J functions as an essential plug-in option module for the SIPART PS2 series of electropneumatic positioners. This specific unit facilitates the transmission of precise position feedback via an analog 4 to 20 mA signal, allowing control systems to monitor valve stroke status continuously. Because it adheres to the EEx ib intrinsic safety standard, engineers integrate this module confidently into hazardous environments common in chemical processing, oil and gas, and pharmaceutical manufacturing. Furthermore, the compact design enables rapid installation within existing SIPART PS2 housings, which minimizes field maintenance time and operational disruption.

Technical Specifications

  • Model Number: 6DR4004-6J
  • Manufacturer: Siemens
  • Product Category: Position Feedback Module (Analog Output)
  • Compatibility: SIPART PS2 Electropneumatic Positioners
  • Output Signal: 4 to 20 mA
  • Protection Class: EEx ib (Intrinsically Safe)
  • Installation Type: Internal Plug-in
  • Weight: 0.08 kg
  • Dimensions: 2.2 cm x 14.3 cm x 12.6 cm
  • HS Code: 8537101190

Industrial Applications and Performance

System integrators utilize the 6DR4004-6J to enhance the diagnostic capabilities of automated valve assemblies. By converting mechanical stem position into a standardized electrical current, the module empowers operators to detect valve degradation early through predictive maintenance analysis. Additionally, the electronic architecture provides superior noise immunity, which ensures that feedback signals remain stable even when operating near high-power industrial machinery.

Because this module operates as a direct extension of the SIPART PS2 system, it requires no extensive re-configuration of the control loop. Maintenance teams simply mount the module onto the main board, and the positioner automatically recognizes the new feedback capability. Consequently, this device serves as a highly efficient upgrade for legacy installations, effectively modernizing older flow control architectures without necessitating a complete overhaul of the instrumentation. Siemens engineers specifically designed this component to maintain high signal integrity over long cabling runs, thereby facilitating centralized monitoring in complex, large-scale plant infrastructures.