You are here:
SKU: CV-DSC10K

Honeywell CV-DSC10K PlantCruise 10,000 SCADA Points Adder

Honeywell CV-DSC10K software licensing expansion module adding 10,000 SCADA data points for PlantCruise and Experion LX architectures. Factory new, fully documented.

The Honeywell CV-DSC10K functions as a high-capacity software licensing expansion mechanism utilized to scale data ingestion boundaries across Honeywell PlantCruise and Experion LX Distributed Control Systems (DCS). Rather than acting as a physical input/output hardware card, this specific part number delivers a digital authentication entitlement that authorizes 10,000 additional concurrent SCADA runtime data tags (points) within the supervisory database tier. The addition permits control engineers to register, trend, and alarm extra field metrics without upgrading central processing servers.

Hardware Licensing Specifications

ParameterSpecification
Model / Catalog NumberCV-DSC10K
BrandHoneywell
OriginUSA
Shipping Weight0.4 kg (Includes physical documentation/dongle package)
Package Dimensions7 x 14 x 14.5 cm
Module TypePlantCruise 10,000 SCADA Points Adder
System EnvironmentPlantCruise / Experion LX / Experion HMI
FunctionalityDigital Database Tag Expansion
Data Integration LinkBackplane registry validation via server software interface

Process Control & Database Tag Allocation

The Honeywell CV-DSC10K is critical for large-scale production updates that introduce new instrumentation networks into a processing facility. When field buses gather telemetry from added equipment, the central system database maps those elements to distinct SCADA tags. Implementing this points adder expands system memory slots to safely handle telemetry, diagnostic reporting, and alarm limits alongside standard 4-20 mA HART loop protocol registries and discrete control sequences, keeping channel-to-channel communication seamless and secure.

Frequently Asked Questions

Q: Is this license tied to a specific server hardware address or a physical USB key?

A: Depending on the system architecture generation, the CV-DSC10K license is either bound directly to the primary server’s unique system ID or loaded onto a physical hardware security dongle inside the cabinet.

Q: Can multiple CV-DSC10K points adders be stacked together on a single SCADA server node?

A: Yes. Multiple point adder certificates can typically be stacked on a single server node up to the maximum database tag boundary dictated by the primary PlantCruise or Experion LX framework version.

Q: Does installing this points adder require taking the active control room runtime offline?

A: No. Licensing expansions are usually validated through the engineering studio utility and can be loaded dynamically, avoiding downtime for active control loops.


Field Installation Guidelines

  • Database Configuration Save: Execute a full system check and back up the current SCADA database before activating the license key.
  • Licensing Key Validation: Input the authorization string via the Honeywell License Manager software. Ensure the key exactly matches the system serial registration number to prevent configuration lockouts.
  • Server Performance Monitoring: Once the 10,000 extra points are added, monitor server CPU usage and memory loads to make sure the server hardware can process the new communication load cleanly.